44 Advantage of vacuum CB * Used up to 66 KV. * Vacuum is highly dielectric, so arc can’t persists. * Separation of contacts causes the release of metal vapour. Source:Electric Substation Types The main purposes for establishment of a substation are: * Need for connecting a generator to the transmission system: We . Replacement of the existing 7 MVA (2 MVA & 5 MVA 66kV: kV transformers) switchyard with a new 66 kV switchyard consisting of two new 10 MVA DSC

Author: Mezilkree Gucage
Country: Ethiopia
Language: English (Spanish)
Genre: Music
Published (Last): 28 February 2005
Pages: 214
PDF File Size: 16.79 Mb
ePub File Size: 10.2 Mb
ISBN: 412-5-25998-298-7
Downloads: 15998
Price: Free* [*Free Regsitration Required]
Uploader: Dobei

Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose. From Wikipedia, the free encyclopedia.

A disconnect switch is used to provide isolation, since it cannot interrupt load current. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers.

Electrical substation – Wikipedia

To maintain reliability of supply, companies aim at keeping the system up and running while performing maintenance. They feed synchronizing equipment.

The magnitude of the current transformer outputs may be used to trip the circuit breaker resulting in a disconnection of the load supplied by the circuit break from the feeding point.

The switchgears shall be equipped with Vacuum circuit breaker.

Between the generating station and consumer, electric power may flow through several substations at different voltage levels. Control voltage shall be V DC. Sometimes they are also transmission substations or collector substations if k.v.swirchyard railway network also operates its own grid 66 generators to supply the other stations.

  GIEDION SPAZIO TEMPO ARCHITETTURA PDF

Two sets of Capacitor bank shall be installed outdoor. They are used to isolate or deenergize equipment for. Converter substations may be associated with HVDC converter plants, traction currentor interconnected non-synchronous networks. United States Department of Agriculture.

Each sub bank shall be k.f.switchyard with motorized 11KV Isolator. Substations may be described by their voltage class, their applications within the power system, the method used to insulate most connections, and by the style and materials of the structures used. Former high-voltage substation in Stuttgart, Germany, now kV switching station.

SWITCHYARD www.powerpointpresentationon.blogspot.com.

Published by Suzanna Stewart Modified over k.v.switchhard years ago. Retrieved from ” https: A switching station may also be known as a switchyard, and these are commonly located directly adjacent to or nearby a power station. My presentations Profile Feedback Log out. Along with this, a substation always has control circuitry needed to command the various circuit breakers to open in case of the failure of some component.

Instead of bare conductors, bus and k.v.swltchyard are built into pressurized tubular containers filled with sulfur hexafluoride SF 6 gas.

Auth with social network: Substations transform voltage from high to low, or the reverse, or perform any of several other important functions.

Puffer cylinder Interrupter 9. Where space is plentiful and appearance of the station is not a factor, steel lattice towers provide low-cost supports for transmission lines k.v.switchyrd apparatus. Breaking Capacity Max fault current at which a CB is capable of breaking a circuit. The Control supply shall be V DC.

  EXERCICE CORRECTION TRANSISTOR BIPOLAIRE PDF

This page was last edited on 5 Decemberat A switching station is a substation without transformers and operating only at a single voltage level. Formerly rotary converters changed frequency to interconnect two systems; nowadays such substations are rare. Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by d shielding the overhead lines.

These categories are not disjointed; for example, to solve a particular problem, a transmission substation may include significant distribution functions. Switches, circuit breakers, transformers and other apparatus may be interconnected by air-insulated bare conductors strung on support structures. The substation site must be reasonably central to the distribution area to be served. The downtown areas of large cities feature complicated distribution substations, with high-voltage switching, and switching and backup systems on the low-voltage side.

Indoor substations may be gas-insulated switchgear at high voltagesor metal-enclosed or metal-clad switchgear at lower voltages. Share buttons are a little bit lower. Other devices such as capacitors and voltage regulators may also be located at a substation. Electrified railways also use substations, often distribution substations. They measure voltage and in conjunction with CTthey measure power. By using this site, you agree to the Terms of Use and K.v.switchyagd Policy.